Back to Search
VICKEN VORPERIAN, MD
MD
Clinical Cardiac Electrophysiology Physician
NPI: 1235106089Individual
Specialties, Licenses & Credentials
Clinical Cardiac Electrophysiology PhysicianPrimary
Internal Medicine — Clinical Cardiac Electrophysiology
Code: 207RC0001X
34682(WI)
Research & Publications (18)
Lesion size estimator of cardiac radiofrequency ablation at different common locations with different tip temperatures.
PMID 15490835·IEEE Trans Biomed Eng·2004
4-observational
In vitro measurement of myocardial impedivity anisotropy with a miniature rectangular tube.
PMID 12723067·IEEE Trans Biomed Eng·2003
4-observational
Noncontact radio-frequency ablation for obtaining deeper lesions.
PMID 12665035·IEEE Trans Biomed Eng·2003
7-preclinical
FEM analysis of predicting electrode-myocardium contact from RF cardiac catheter ablation system impedance.
PMID 12046696·IEEE Trans Biomed Eng·2002
4-observational
Error analysis of tissue resistivity measurement.
PMID 12002180·IEEE Trans Biomed Eng·2002
7-preclinical
In-vivo measurement of swine myocardial resistivity.
PMID 12002179·IEEE Trans Biomed Eng·2002
7-preclinical
Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation.
PMID 11876289·IEEE Trans Biomed Eng·2002
7-preclinical
Three-Dimensional finite-element analyses for radio-frequency hepatic tumor ablation.
PMID 11797653·IEEE Trans Biomed Eng·2002
8-other
Modeling bipolar phase-shifted multielectrode catheter ablation.
PMID 11794767·IEEE Trans Biomed Eng·2002
8-other
Flow effect on lesion formation in RF cardiac catheter ablation.
PMID 11322530·IEEE Trans Biomed Eng·2001
7-preclinical
Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablation.
PMID 11296875·IEEE Trans Biomed Eng·2001
8-other
Thermal--electrical finite element modelling for radio frequency cardiac ablation: effects of changes in myocardial properties.
PMID 11094815·Med Biol Eng Comput·2000
8-other
Temperature measurement within myocardium during in vitro RF catheter ablation.
PMID 11077746·IEEE Trans Biomed Eng·2000
7-preclinical
Dependence of apparent resistance of four-electrode probes on insertion depth.
PMID 10646278·IEEE Trans Biomed Eng·2000
8-other
Finite element analyses of uniform current density electrodes for radio-frequency cardiac ablation.
PMID 10646277·IEEE Trans Biomed Eng·2000
8-other
A new catheter design using needle electrode for subendocardial RF ablation of ventricular muscles: finite element analysis and in vitro experiments.
PMID 10646276·IEEE Trans Biomed Eng·2000
7-preclinical
Data courtesy of the U.S. National Library of Medicine (NLM). Ltrl is not affiliated with or endorsed by NLM.
Contact & Hours
- Address
- 725 AMERICAN AVE SUITE 410, PROHEALTH CARE MEDICAL ASSOCIATES CARDIOLOGY
WAUKESHA, WI 53188 - Phone
- (262) 928-8300
Quick Facts
- NPI
- 1235106089
- Entity Type
- Individual
- Gender
- Male
- Medicare
- Not confirmed
- Specialties
- 1
- Locations
- 1
- Publications
- 18
Are you this provider?
Claim Your Profile